Product index
Optical access, fiber power and the copper edge.
29 product pages across 9 families, specified as one optical budget. Start from the configuration family, then confirm ports, power and connector polish on the quotation.
- Families
- 9
- Product pages
- 29
- PON reach
- 20 km
- PoF reach
- 200 m

01 / EPON · GPON · XGS-PON
PON access
OLT, ONU/ONT and PLC splitters sized as one optical budget.

PON access · OLT
GPON OLT
From a 1-PON gateway to a 112-PON headend.
GPON OLT platforms for FTTH, campus and hotel access: 2.5 Gbps downstream and 1.25 Gbps upstream, 1:64 split per PON port and 20 km reach on Class B+ optics. Configurations run from a compact 1-PON gateway with built-in AC to a chassis with up to 112 PON ports.
- Line rate
- 2.5 Gbps ↓ / 1.25 Gbps ↑
- Max split
- 1:64 per PON port
- Reach
- 20 km, Class B+
- PON ports
- 1 – 112
Best for FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage
View specifications
PON access · OLT
8-Port EPON OLT
1U, eight EPON ports, up to 512 ONUs.
A 1U EPON OLT with eight PON ports, 16 uplink ports and a 128 Gbps backplane. It supports 1:64 splitting, 20 km reach and up to 512 ONUs, making it a compact headend for CCTV, campus and small FTTH networks.
- PON ports
- 8 × EPON
- Line rate
- 1.25 Gbps symmetric
- Max ONUs
- 512 (64 per port)
- Backplane
- 128 Gbps
Best for CCTV & Surveillance Power · Campus Fibre Network · FTTH Access Network
View specifications
PON access · 10G OLT
10G PON / XGS-PON OLT
XGS-PON and 10G PON boards in one chassis.
A chassis OLT for XGS-PON, XG-PON and 10G EPON access: up to 112 PON ports across seven service boards, 100GE uplinks and coexistence with an existing GPON ODN. The PON generation and port count are confirmed by the board mix.
- PON generation
- XGS-PON / XG-PON / 10G EPON
- Line rate
- 10G symmetric (XGS-PON)
- Max PON ports
- 112
- Uplink
- 2× 100GE QSFP28
Best for FTTH Access Network · Campus Fibre Network
View specifications
PON access · ONU / ONT
GPON / XPON ONU & ONT
From a 1-GE bridge to a 4-GE Wi-Fi 6 gateway.
XPON ONU and ONT options for FTTH, hotel rooms, offices and outdoor cabinets: 1, 2 or 4 GE ports, Wi-Fi 4/5/6, CATV and POTS options, and 10G PON models. All units are SC single-mode, 20 km, EPON/GPON dual-mode where the model supports it.
- PON
- XPON, EPON/GPON
- User ports
- 1 – 4 × GE
- Wi-Fi
- Wi-Fi 4 / 5 / 6
- Reach
- 20 km
Best for FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage
View specifications
PON access · 10G ONU
10G PON ONU
XG(S)-PON and 10G EPON subscriber units.
10G PON ONU options for business and premium FTTH: 10G EPON, XG-PON and XGS-PON models with 10GE/2.5GE LAN, Wi-Fi 6 and POTS options. The port mix and PON mode are confirmed per model.
- PON
- XGS-PON / XG-PON / 10G EPON
- LAN
- 1× 10GE + 1–4 GE
- Wi-Fi
- Wi-Fi 6 AX3000
- Reach
- 20 km
Best for FTTH Access Network · Campus Fibre Network
View specifications
PON access · hardened ONU
Industrial & Outdoor ONU
Wide temperature, outdoor integrated, 6 kV surge.
Hardened ONU options for poles, cabinets and plants: wide-temperature models, outdoor integrated ONUs with power and surge protection, industrial ONUs and DIN-rail or IP-rated enclosures. Ports and temperature ratings are confirmed per model.
- Temperature
- −40 to +70 °C
- Surge
- 6 kV
- Mounting
- Pole / DIN / wall
- Ports
- 1–4 GE
Best for Industrial & Tunnel Network · Perimeter Security Power · Parking Lot Camera System
View specifications
PON access · PoE ONU
PoE ONU & Reverse PoE
Power the ONU from the LAN, or the LAN from the ONU.
PoE ONU variants for corridors, rooms and MDUs: reverse-PoE (PD) units powered by a PoE switch, PSE units that power cameras and APs, and 4/8/24-port models for floor distribution. One XPON uplink, up to 24 PoE outputs.
- Uplink
- XPON / 10G PON
- PoE ports
- 1 – 24
- Modes
- PSE / PD
- Power
- 802.3af/at
Best for CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage
View specifications
PON access · ODN
Fiber Optic Splitter (PLC)
1×2 to 1×64, SC/UPC or SC/APC.
Planar lightwave circuit splitters from 1×2 to 1×64 for PON ODN construction. Typical insertion loss runs from 3.6 dB at 1×2 to 20.5 dB at 1×64; each batch ships with test data and the connector polish you specify.
- Ratios
- 1×2 – 1×64
- Wavelength
- 1260 – 1650 nm
- Insertion loss
- 3.6 – 20.5 dB
- Connector
- SC/UPC / SC/APC
Best for FTTH Access Network · Campus Fibre Network · CCTV & Surveillance Power
View specifications02 / Hybrid cable · 200 m
Power over Fiber
Data and 48 V DC on one cable, up to 12 W per port.

Power over Fiber · access
PoF Switch & PoF ONU
One hybrid cable to the ceiling: data and 12 W.
A Power-over-Fiber access set: an optical gateway, an 8-output PoF power splitter, hybrid PoF cable and a ceiling Wi-Fi 6 ONU. Each output delivers up to 12 W to 200 m, so ceiling APs and cameras run without a local mains socket.
- Power per port
- Up to 12 W
- Reach
- Up to 200 m
- Outputs
- 8 + 1 cascade
- Wi-Fi
- Wi-Fi 6 AX3000
Best for Outdoor Wireless Coverage · Campus Fibre Network · Parking Lot Camera System
View specifications
Power over Fiber · splitter
PoF Power Splitter
Eight outputs, 12 W each, one cascade port.
A 1×9 PoF power splitter that combines an optical splitter and a 48 V DC power distributor in one box. It feeds eight PoF ONUs at up to 12 W each to 200 m and provides a cascade port for a second splitter.
- Split
- 1×9 (8 + cascade)
- Output power
- ≤12 W per port
- Supply
- 48 V DC, 120 W
- Insertion loss
- ≤16.5 dB output
Best for Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power
View specifications
Power over Fiber · cable
Hybrid PoF Cable
G.657A2 fibre and copper in one flat jacket.
A flat hybrid cable with one G.657A2 fibre and a copper pair, terminated SC/UPC and supplied in 3, 20 or 50 m lengths. Attenuation is ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm; the jacket is rated −20 to +80 °C.
- Fibre
- G.657A2, single core
- Attenuation
- ≤0.4 / ≤0.3 dB/km
- Lengths
- 3 / 20 / 50 m
- Temperature
- −20 to +80 °C
Best for Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power
View specifications03 / 8 – 48 ports · 10G/100G
PoE & aggregation switching
Copper edge switching, PoE budgets and 10G/100G aggregation.

PoE switching · managed & unmanaged
PoE Switches
8 to 48 PoE ports, with 10G and 100G uplinks.
PoE switch families from compact 4–8 port units to 48-port Layer 3 switches with 100G uplinks. IEEE 802.3af/at power, VLAN and IGMP isolation, and a 100 m copper limit that decides where the fibre has to take over.
- Ports
- 4 – 48 × GE PoE
- Uplinks
- GE / 10G / 100G
- Power
- 802.3af / at
- Distance
- 100 m copper
Best for CCTV & Surveillance Power · Parking Lot Camera System · Perimeter Security Power
View specifications
PoE switching · compact
8-Port PoE Switch
Small-count PoE for poles, kiosks and shops.
Compact 4- and 8-port PoE switches for small camera groups, wireless APs and access control. Fanless, desktop or wall mounted, with 802.3af/at power and a GE or SFP uplink.
- Ports
- 4 or 8 × GE PoE
- Power
- 802.3af / at
- Cooling
- Fanless
- Mount
- Desktop / wall
Best for CCTV & Surveillance Power · Parking Lot Camera System · Bollard & Access Control Power
View specifications
PoE switching · 24 port
24-Port PoE Switch
24 PoE ports and four 10G uplinks in 1U.
A 1U Layer 2/Layer 3 PoE switch with 24 GE PoE access ports and four 10GE/GE SFP+ uplinks. It is the standard choice for a CCTV floor, a wireless floor or a building distribution cabinet.
- Access ports
- 24 × GE PoE
- Uplinks
- 4 × 10GE SFP+
- Management
- L2 / L3
- Form factor
- 1U rack
Best for CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage
View specifications
PoE switching · hardened
Industrial PoE Switch
Hardened switching for tunnels, roads and plants.
Industrial PoE switching specified per project: DIN-rail mounting, wide-temperature operation, redundant DC input, higher surge immunity and ring recovery for tunnels, highways, plants and perimeter sites.
- Mounting
- DIN rail / wall
- Temperature
- Wide-range model
- Power
- Redundant DC
- Network
- Ring / RSTP
Best for Industrial & Tunnel Network · Perimeter Security Power · Parking Lot Camera System
View specifications
Switching · aggregation
10G / 100G Aggregation Switches
L3 aggregation for campus and data-centre edge.
Layer 3 aggregation switches for campus cores and data-centre edge: 12–24 × 10GE SFP+ ports, 100GE QSFP28 uplinks, and 24/48-port GE models with 10G uplinks. The port mix and routing feature set are confirmed per model.
- 10G ports
- 12 – 24 × SFP+
- 100G uplinks
- 2× QSFP28
- Management
- L3
- Form factor
- 1U
Best for Campus Fibre Network · CCTV & Surveillance Power · Industrial & Tunnel Network
View specifications04 / 1550 nm · CATV
Optical transmission
Transmitters, EDFAs and CATV receivers for overlay and long haul.

Optical transmission · 1550 nm
EDFA & 1550 nm Transmitter
CATV overlay and long-haul 1550 nm transport.
1550 nm optical transmitters and erbium-doped fibre amplifiers for CATV overlay and long-distance transport: direct-modulated 10 dBm and external-modulated 7/9 dBm transmitters, plus 4/8/16/32-port EDFA units at 19/22 dBm.
- Wavelength
- 1550 nm
- EDFA ports
- 4 / 8 / 16 / 32
- Output power
- 19 / 22 dBm
- Transmitter
- 7 / 9 / 10 dBm
Best for Campus Fibre Network · FTTH Access Network
View specifications
Optical transmission · transmitter
1550 nm Optical Transmitter
Direct 10 dBm and external 7/9 dBm.
1550 nm transmitters for CATV overlay and long-haul transport: direct-modulated 10 dBm and externally modulated 7/9 dBm units, with 47–1000 MHz RF input and optical output for EDFA chains.
- Wavelength
- 1550 nm
- Output
- 7 / 9 / 10 dBm
- Modulation
- Direct / external
- RF
- 47–1000 MHz
Best for FTTH Access Network · Campus Fibre Network
View specifications
Optical transmission · receiver
CATV Optical Receiver
1550 nm to RF, with AGC options.
CATV optical receivers for FTTH and building distribution: 1550 nm input, 47–1000 MHz RF output, 75 Ω, AGC options and +2 to −18 dBm input range. Models with PON and CATV ports are available for triple-play ONUs.
- Wavelength
- 1550 ± 10 nm
- Input range
- +2 to −18 dBm
- RF band
- 47–1000 MHz
- Impedance
- 75 Ω
Best for FTTH Access Network · Campus Fibre Network
View specifications05 / Wi-Fi 6/7 · 4G/5G
CPE & wireless
Routers, 4G/5G CPE and ceiling, wall-plate or high-density access points.

CPE & wireless · router
Router / CPE
Wi-Fi 6 routers for FTTH and SMB.
Router / CPE options for FTTH and SMB: Wi-Fi 6 AX1500 and AX3000, 1–4 GE ports, 2.5GE WAN, PoE PD and a ceiling-mount model with AP function. Fat/fit modes let the same unit work as a router or an access point.
- Wi-Fi
- Wi-Fi 6 AX1500 / AX3000
- Ports
- 1–4 GE
- WAN
- GE / 2.5GE
- Power
- DC / PoE PD
Best for FTTH Access Network · Campus Fibre Network
View specifications
CPE & wireless · mobile access
4G / 5G CPE
LTE and 5G routers for sites without fibre.
4G / 5G CPE for temporary, remote and backup access: 5G/4G models with 1–3 GE, USIM, Wi-Fi 6, and LTE CAT6/CAT4 models with 1–4 FE/GE, RJ11 and battery options.
- Cellular
- 5G / 4G LTE
- Ports
- 1–4 FE / GE
- Wi-Fi
- Wi-Fi 4 / 5 / 6
- SIM
- USIM
Best for Industrial & Tunnel Network · Campus Fibre Network · FTTH Access Network
View specifications
CPE & wireless · access points
Wi-Fi AP & AC
Ceiling, wall-plate and high-density APs.
Wi-Fi 6/7 access points and software AC for hotels, campuses and offices: ceiling APs with 2.5GE PoE, wall-plate APs, high-density models, PoF ceiling APs and a built-in or software AC.
- Wi-Fi
- Wi-Fi 6 / Wi-Fi 7
- Uplink
- GE / 2.5GE / PoF
- Power
- PoE / PoF
- Management
- AC / OLT
Best for Campus Fibre Network · Outdoor Wireless Coverage · FTTH Access Network
View specifications06 / ODF · cords · SFP · SPD
ODN & accessories
ODF and enclosures, patch cords, SFP optics, surge protection and copper cabling.

ODN & accessories · enclosures
ODF & Fiber Enclosures
Rack ODF, wall boxes and splice closures.
Passive enclosures for the ODN: 1U rack ODFs, wall-mount distribution boxes, splice closures and terminal boxes, with SC/UPC or SC/APC adapters and 4–96 port options. The enclosure format follows the installation point.
- Formats
- 1U / wall / closure
- Ports
- 4 – 96
- Adapter
- SC/UPC / SC/APC
- Mount
- Rack / wall / pole
Best for FTTH Access Network · Campus Fibre Network · Industrial & Tunnel Network
View specifications
ODN & accessories · optics
SFP & SFP+ Transceivers
1G/10G optics for PON, switches and uplinks.
SFP and SFP+ optical transceivers for PON ports, switch uplinks and 1550 nm links: 1G/10G, 1310/1490/1550 nm, 20/40/80 km, SC/LC, EPON PX20++/+++ and GPON Class B+/C+ options. The exact optic is confirmed with the OLT or switch model.
- Rate
- 1G / 10G
- Reach
- 20 / 40 / 80 km
- Wavelength
- 1310 / 1490 / 1550 nm
- Connector
- SC / LC
Best for FTTH Access Network · Campus Fibre Network · Industrial & Tunnel Network
View specifications
ODN & accessories · protection
Surge Protection & Installation Accessories
SPDs, grounding and weatherproof installation.
Surge protective devices and installation accessories for outdoor PoE, PoF and ODN sites: Type 2 Ethernet/PoE SPDs, 48 V DC power SPDs, grounding kits, cable glands and IP-rated enclosures.
- Type
- Type 2 SPD
- Surge
- 6 kV class
- Mount
- DIN / wall
- Enclosure
- IP66 / IP68
Best for Perimeter Security Power · Parking Lot Camera System · Industrial & Tunnel Network
View specifications07 / NVR · ONVIF
Surveillance storage
NVR and surveillance storage quoted with the camera network.
08 / OMCI · SNMP · cloud
Software & management
OLT management, TR-069 ACS and cloud platform for multi-site networks.
09 / Patch cords · copper
Cable assemblies & copper
Fibre patch cords, copper cabling and the passive parts between.

ODN & accessories · fiber cords
Patch Cords, Pigtails & Adapters
SC/LC, UPC/APC, simplex and duplex.
Fiber patch cords, pigtails and adapters for OLT/ODF/ONU links: SC/LC, UPC/APC, simplex/duplex, G.657A2/G.652D, 1–3 m standard lengths, with insertion loss and return loss test data. MPO breakout and copper patch cords are available.
- Connector
- SC / LC
- Polish
- UPC / APC
- Fiber
- G.657A2 / G.652D
- Length
- 1 / 2 / 3 m
Best for FTTH Access Network · Campus Fibre Network · CCTV & Surveillance Power
View specifications
ODN & accessories · copper
Copper Cabling & Accessories
Cat5e/Cat6 panels, jacks, faceplates and reels.
Copper cabling for the PoE edge: Cat5e/Cat6 patch panels, keystone jacks, faceplates, cable reels and patch cords. The copper plant is part of the PoE budget and the 100 m channel, not a separate afterthought.
- Category
- Cat5e / Cat6
- Panel
- 12 / 24 / 48 ports
- Reel
- 305 m
- Channel
- 100 m
Best for CCTV & Surveillance Power · Campus Fibre Network · Parking Lot Camera System
View specificationsProduct comparison
29 products, one table.
Open the full comparison to scan configuration, key specifications and typical applications across every family. Use the category sections above when you want the visual view.
Open the 29-product comparison table29
| Product | Family | Key specifications | Best for | Link |
|---|---|---|---|---|
| GPON OLTPON access · OLT | PON access |
| FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage | View product |
| 8-Port EPON OLTPON access · OLT | PON access |
| CCTV & Surveillance Power · Campus Fibre Network · FTTH Access Network | View product |
| GPON / XPON ONU & ONTPON access · ONU / ONT | PON access |
| FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage | View product |
| PoF Switch & PoF ONUPower over Fiber · access | Power over Fiber |
| Outdoor Wireless Coverage · Campus Fibre Network · Parking Lot Camera System | View product |
| PoF Power SplitterPower over Fiber · splitter | Power over Fiber |
| Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power | View product |
| Hybrid PoF CablePower over Fiber · cable | Power over Fiber |
| Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power | View product |
| PoE SwitchesPoE switching · managed & unmanaged | PoE & aggregation switching |
| CCTV & Surveillance Power · Parking Lot Camera System · Perimeter Security Power | View product |
| 8-Port PoE SwitchPoE switching · compact | PoE & aggregation switching |
| CCTV & Surveillance Power · Parking Lot Camera System · Bollard & Access Control Power | View product |
| 24-Port PoE SwitchPoE switching · 24 port | PoE & aggregation switching |
| CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage | View product |
| Industrial PoE SwitchPoE switching · hardened | PoE & aggregation switching |
| Industrial & Tunnel Network · Perimeter Security Power · Parking Lot Camera System | View product |
| Fiber Optic Splitter (PLC)PON access · ODN | PON access |
| FTTH Access Network · Campus Fibre Network · CCTV & Surveillance Power | View product |
| EDFA & 1550 nm TransmitterOptical transmission · 1550 nm | Optical transmission |
| Campus Fibre Network · FTTH Access Network | View product |
| PoE ONU & Reverse PoEPON access · PoE ONU | PON access |
| CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage | View product |
| 10G PON / XGS-PON OLTPON access · 10G OLT | PON access |
| FTTH Access Network · Campus Fibre Network | View product |
| 10G PON ONUPON access · 10G ONU | PON access |
| FTTH Access Network · Campus Fibre Network | View product |
| Industrial & Outdoor ONUPON access · hardened ONU | PON access |
| Industrial & Tunnel Network · Perimeter Security Power · Parking Lot Camera System | View product |
| 10G / 100G Aggregation SwitchesSwitching · aggregation | PoE & aggregation switching |
| Campus Fibre Network · CCTV & Surveillance Power · Industrial & Tunnel Network | View product |
| 1550 nm Optical TransmitterOptical transmission · transmitter | Optical transmission |
| FTTH Access Network · Campus Fibre Network | View product |
| CATV Optical ReceiverOptical transmission · receiver | Optical transmission |
| FTTH Access Network · Campus Fibre Network | View product |
| Router / CPECPE & wireless · router | CPE & wireless |
| FTTH Access Network · Campus Fibre Network | View product |
| 4G / 5G CPECPE & wireless · mobile access | CPE & wireless |
| Industrial & Tunnel Network · Campus Fibre Network · FTTH Access Network | View product |
| Wi-Fi AP & ACCPE & wireless · access points | CPE & wireless |
| Campus Fibre Network · Outdoor Wireless Coverage · FTTH Access Network | View product |
| ODF & Fiber EnclosuresODN & accessories · enclosures | ODN & accessories |
| FTTH Access Network · Campus Fibre Network · Industrial & Tunnel Network | View product |
| Patch Cords, Pigtails & AdaptersODN & accessories · fiber cords | Cable assemblies & copper |
| FTTH Access Network · Campus Fibre Network · CCTV & Surveillance Power | View product |
| SFP & SFP+ TransceiversODN & accessories · optics | ODN & accessories |
| FTTH Access Network · Campus Fibre Network · Industrial & Tunnel Network | View product |
| Surge Protection & Installation AccessoriesODN & accessories · protection | ODN & accessories |
| Perimeter Security Power · Parking Lot Camera System · Industrial & Tunnel Network | View product |
| Copper Cabling & AccessoriesODN & accessories · copper | Cable assemblies & copper |
| CCTV & Surveillance Power · Campus Fibre Network · Parking Lot Camera System | View product |
| NVR & Surveillance StorageSurveillance · storage | Surveillance storage |
| CCTV & Surveillance Power · Parking Lot Camera System · Perimeter Security Power | View product |
| Network Management & Cloud PlatformSoftware · management | Software & management |
| FTTH Access Network · Campus Fibre Network · Industrial & Tunnel Network | View product |
Specifications are configuration-family ratings; model-level values are confirmed on the quotation.
Selection matrix
All families, one comparison.
The numbers below are the ones that decide the architecture: reach, power, split and port count. Model-level detail is in each product page and on the quotation.
| Family | Key reach / rate | Ports or outputs | Power / split | Typical use |
|---|---|---|---|---|
| PON access | 20 km, 2.5G/1.25G GPON | 1–112 PON ports | 1:64 max split | FTTH, campus, hotel |
| PoF | 200 m per port | 8 outputs + cascade | 12 W per port | Ceiling APs, pole cameras |
| PoE switching | 100 m copper | 4–48 PoE ports | 802.3af / at | CCTV, Wi-Fi, access control |
| Optical transport | 1550 nm, long haul | 4–32 EDFA ports | 19 / 22 dBm | CATV overlay, district links |
| Cable assemblies & copper | 3–50 m / Cat5e–Cat6 | Patch cords, copper | SC/LC, UPC/APC | Last-metre and copper edge |
| CPE & wireless | Wi-Fi 6/7, 4G/5G | 1–4 GE / 2.5GE | PoE / PoF | Router, AP, mobile access |
| ODN & accessories | 4–96 ports / 1G–10G | ODF, cords, SFP, SPD | SC/LC, UPC/APC | Passive plant and protection |
| Surveillance & software | 8–64 ch NVR; OMCI/SNMP | NVR, ACS, cloud | ONVIF, TR-069 | Recording and management |
Product FAQ
What buyers ask before choosing a family.
If your question is not here, send the site details and we will answer with the calculation, not a brochure.
Ask an engineerWhere should a project start: OLT, ONU or cable?
Start with the endpoint list and the distance. The endpoint count sets the ONU and port count; the distance and split ratio set the OLT optical budget; the power condition decides whether the last 100 m is copper or PoF. The product order follows the design, not the other way round.
Can I buy the OLT and ONUs separately?
Yes, but the PON mode, optical class, connector polish and management profile must match. We confirm the pair before shipment and can supply the full chain as one bill of materials.
Do you list model codes and prices on the site?
Model codes for datasheet-backed models are in the model library; prices are confirmed on the quotation for the selected configuration. Product pages publish configuration families and their verified optical, power and port ratings.
What is the difference between the PoF pages and the PoE pages?
PoE sends power over copper Ethernet within 100 m. PoF sends power over a copper pair inside a hybrid cable, alongside a fibre, up to 200 m. The product pages are separate because the cable, splitter and ONU are a different chain.
Which family is the volume driver for a CCTV project?
The PoE switches and the PON access chain. PoE covers the copper edge; the OLT/ONU/splitter chain covers the backbone and the remote cabinets. PoF is used only for the endpoints without mains.
Why do some products show configuration ranges instead of one model?
Because the exact model is confirmed against the site data and the quotation. The page shows the family boundaries — port count, optical reach, power and split — while models with a complete project datasheet also have a dedicated model page. This avoids publishing a model code that does not match the ordered configuration.
Next step
Tell us the endpoint count and the longest run.
We return the optical budget, the PoE/PoF load and a bill of materials. If the design is ambiguous, we show both options and the trade-off.
No obligation. The plan states its assumptions so your engineer can check it.