PON access · hardened ONU

Industrial & Outdoor ONU

Hardened ONU options for poles, cabinets and plants: wide-temperature models, outdoor integrated ONUs with power and surge protection, industrial ONUs and DIN-rail or IP-rated enclosures. Ports and temperature ratings are confirmed per model.

Updated October 24, 2026

Temperature
−40 to +70 °C
Surge
6 kV
Mounting
Pole / DIN / wall
Ports
1–4 GE
Hardened ONU for outdoor and industrial cabinets

The short answer

What this product is specified for.

−40 to +70 °C6 kV surgePole / DINPoE / PoF options

Included in the quotation

  • Port count, connector polish and power configuration
  • Model-level datasheet and test data
  • Optical budget and splitter plan for the ODN
  • Export packing, HS code and Incoterm

A standard ONU belongs in a conditioned room. A pole, a roadside cabinet, a tunnel or a plant floor is a different environment: heat, cold, vibration, dust and lightning-induced surges. The hardened ONU family is specified for the internal cabinet temperature and the surge exposure, not for a comfortable office.

The configurations follow the mounting point. A wide-temperature ONU covers a ventilated cabinet from −40 to +55 °C; an industrial ONU extends to −40 to +70 °C with 6 kV surge protection and a DIN-rail or wall mount; an outdoor integrated ONU puts power, surge protection and communication in one pole-mounted unit. Standard ONUs can also be used inside an IP-rated enclosure when the budget is tighter, but the enclosure and SPD become part of the design.

Port counts and interfaces are model-specific. Most units provide 1–4 GE ports, with optional PoE or PoF variants for cameras and APs. The model datasheet, the enclosure IP rating and the SPD are confirmed together so the ONU is not the weak point in an outdoor cabinet.

Configuration table

The numbers that decide the fit.

Values are from the model datasheet. Where a value is model-dependent, the table says so instead of guessing.

TypeTemperatureSurgeMountingTypical use
Wide-temperature ONU−40 to +55 °CModel-dependentDIN rail / wallVentilated cabinet
Industrial ONU−40 to +70 °C6 kVDIN rail / wallPlant, tunnel, roadside
Outdoor integrated ONU−40 to +70 °C6 kVPolePerimeter, parking, pole
Standard ONU + IP enclosureDepends on enclosureSPD requiredWall / poleBudget outdoor site

Temperature, surge rating, port count and enclosure IP rating are model-specific. Confirm them together on the quotation.

Engineering features

What changes on site.

Cabinet temperature

Specify the internal cabinet maximum, not the outside air. A sealed cabinet can run 15–20 °C above ambient.

6 kV surge

Industrial models are specified with higher surge immunity; the SPD and bonding at the cabinet entry remain part of the design.

Pole or DIN rail

DIN-rail, wall and pole-mount options; the mounting kit and enclosure are quoted with the ONU.

PoE / PoF options

Selected models provide PoE or PoF outputs for a camera or AP; the power budget is confirmed per model.

One-fibre drop

A single PON drop replaces a copper Ethernet run and its surge path; the ONU terminates the fibre at the cabinet.

Tender documents

Model datasheet, temperature range, surge rating and enclosure IP rating are supplied with the quotation.

Selection guide

Which configuration fits which site.

Start from the site, not from the model. The table is a starting point; the final check is the optical and power budget.

SiteRecommendedWatch-out
Roadside cabinetIndustrial ONU, wide temperatureInternal cabinet temperature and SPD
Perimeter poleOutdoor integrated ONUPole mount, grounding and IP rating
Tunnel / plantIndustrial ONU, DIN railVibration, EMC and redundant power
Budget outdoor siteStandard ONU + IP enclosureEnclosure thermal design and SPD

Do not publish a single industrial temperature for every model; confirm the derating curve for the selected unit.

Integration

Where it sits in the chain.

The PON chain starts at the OLT port, passes through the splitter and the ODN, and ends at the ONU. The split ratio and the connector count decide the optical margin.

  • One bill of materials for the whole chain
  • Connector polish and PON mode confirmed before order
  • Model-level test data supplied with the shipment
Send the site details
GPON access topologyAn OLT connects over up to 20 km of fibre to a 1:32 or 1:64 PLC splitter, which feeds ONUs and ONTs for rooms, cameras, ceiling access points and CATV receivers.HEADENDOLTGPON / EPON / XGS-PON2.5G ↓ / 1.25G ↑20 kmODNPLC splitter1:32 or 1:6416.5 / 20.5 dBSC/UPC or SC/APC3 dB ageing marginONT — guest roomWi-Fi 6 + CATVONU — camera1× GE bridgeONU — ceiling APPoE / PoF optionONT — office4× GE + Wi-Fi 6ONE ODN · SEPARATE VLANS FOR CCTV, DATA, IPTV

Related equipment

Complete the chain.

The product is quoted as part of a chain. These are the parts that usually travel with it.

01XPON ONT with four GE ports, Wi-Fi 6 antennas and USB

PON access · ONU / ONT

GPON / XPON ONU & ONT

From a 1-GE bridge to a 4-GE Wi-Fi 6 gateway.

XPON ONU and ONT options for FTTH, hotel rooms, offices and outdoor cabinets: 1, 2 or 4 GE ports, Wi-Fi 4/5/6, CATV and POTS options, and 10G PON models. All units are SC single-mode, 20 km, EPON/GPON dual-mode where the model supports it.

PON
XPON, EPON/GPON
User ports
1 – 4 × GE
Wi-Fi
Wi-Fi 4 / 5 / 6
Reach
20 km

Best for FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage

View specifications
02PoE ONU with multiple powered Ethernet ports

PON access · PoE ONU

PoE ONU & Reverse PoE

Power the ONU from the LAN, or the LAN from the ONU.

PoE ONU variants for corridors, rooms and MDUs: reverse-PoE (PD) units powered by a PoE switch, PSE units that power cameras and APs, and 4/8/24-port models for floor distribution. One XPON uplink, up to 24 PoE outputs.

Uplink
XPON / 10G PON
PoE ports
1 – 24
Modes
PSE / PD
Power
802.3af/at

Best for CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage

View specifications
03Network equipment under test in a rack room

PoE switching · hardened

Industrial PoE Switch

Hardened switching for tunnels, roads and plants.

Industrial PoE switching specified per project: DIN-rail mounting, wide-temperature operation, redundant DC input, higher surge immunity and ring recovery for tunnels, highways, plants and perimeter sites.

Mounting
DIN rail / wall
Temperature
Wide-range model
Power
Redundant DC
Network
Ring / RSTP

Best for Industrial & Tunnel Network · Perimeter Security Power · Parking Lot Camera System

View specifications
04PoF power splitter with eight optical power outputs

Power over Fiber · access

PoF Switch & PoF ONU

One hybrid cable to the ceiling: data and 12 W.

A Power-over-Fiber access set: an optical gateway, an 8-output PoF power splitter, hybrid PoF cable and a ceiling Wi-Fi 6 ONU. Each output delivers up to 12 W to 200 m, so ceiling APs and cameras run without a local mains socket.

Power per port
Up to 12 W
Reach
Up to 200 m
Outputs
8 + 1 cascade
Wi-Fi
Wi-Fi 6 AX3000

Best for Outdoor Wireless Coverage · Campus Fibre Network · Parking Lot Camera System

View specifications

Product FAQ

Industrial & Outdoor ONU: questions before the order.

If your question is not here, send the site details and we will answer with the calculation, not a brochure.

Ask an engineer

What temperature should an outdoor ONU be rated for?

The internal cabinet temperature at the hottest time of year, not the outside ambient. A sealed cabinet in direct sun can be 15–20 °C above ambient.

Is 6 kV surge enough for a pole?

It is a model rating, not a complete protection plan. Bond the housing and pole, use an SPD at the cabinet entry, and follow the site lightning risk assessment.

Can I use a standard ONU in an outdoor cabinet?

Only inside a suitable IP-rated enclosure with thermal and surge protection. The enclosure, SPD and mounting become part of the design; a standard ONU alone is not an outdoor unit.

Do industrial ONUs support PoE?

Selected models provide PoE or PoF outputs. The budget and port count are model-specific; confirm them against the camera/AP load.

What ports are available?

Most units provide 1–4 GE ports, with optional POTS, CATV, PoE or PoF. The exact mix is confirmed on the model datasheet.

Can I mix industrial and standard ONUs on one OLT?

Yes, if they use the same PON mode and are supported by the OLT firmware. Keep the management profile consistent across the batch.

Next step

Need a Industrial & Outdoor ONU configuration checked?

Send the endpoint count, the longest run, the power condition and the destination. We reply with the configuration, the optical/power budget and the quotation assumptions.

No obligation. The plan states its assumptions so your engineer can check it.