Power over Fiber · access

PoF Switch & PoF ONU

A Power-over-Fiber access set: an optical gateway, an 8-output PoF power splitter, hybrid PoF cable and a ceiling Wi-Fi 6 ONU. Each output delivers up to 12 W to 200 m, so ceiling APs and cameras run without a local mains socket.

Updated October 24, 2026

Power per port
Up to 12 W
Reach
Up to 200 m
Outputs
8 + 1 cascade
Wi-Fi
Wi-Fi 6 AX3000
PoF power splitter with eight optical power outputs

The short answer

What this product is specified for.

12 W per port200 m reach8 + 1 cascadeWi-Fi 6 AX3000

Included in the quotation

  • Port count, connector polish and power configuration
  • Model-level datasheet and test data
  • Optical budget and splitter plan for the ODN
  • Export packing, HS code and Incoterm

PoF here means Power over Fiber in the practical sense used on this site: a hybrid cable that carries one optical fibre and copper conductors in the same jacket. The fibre carries the data; the copper carries 48 V DC. One hybrid cable replaces a fibre drop plus a local mains spur, so a ceiling AP, a camera on a pole or an access-control reader can be installed where there is no socket.

The set is built around an 8-output PoF power splitter. It takes 48 V DC from a 120 W adapter, splits the optical signal 1×9 (eight outputs plus one cascade port) and delivers up to 12 W per output to 200 m. The splitter is a 1×9 PLC with ≤16.5 dB insertion loss on each output and ≤2.3 dB on the cascade port, working from 1260 to 1650 nm with SC/UPC or SC/APC connectors. Power and data leave on the same hybrid cable; the ceiling ONU separates them again.

The ceiling ONU is a Wi-Fi 6 AX3000 access point with one XPON PoF input, one GE port and five internal antennas. It is managed by the optical gateway (1 GPON + 2 GE + 1 10GE SFP+ with a built-in software AC) and supports zero-touch provisioning and seamless roaming. For larger floors, cascade a second splitter from the cascade port; each splitter adds its insertion loss to the optical budget, so check the PON budget before chaining more than two.

Configuration table

The numbers that decide the fit.

Values are from the model datasheet. Where a value is model-dependent, the table says so instead of guessing.

ComponentPortsPower / opticsRole
Optical gateway1× GPON + 2× GE + 1× 10GE SFP+AC input, built-in software ACPON headend and PoF source
PoF power splitter1 input / 8 outputs + 1 cascade48 V DC in/out, 120 W supply, ≤12 W per portSplits optical signal and DC power
PoF ceiling ONU1× XPON PoF + 1× GEFed over the hybrid cable; Wi-Fi 6 AX3000Ceiling Wi-Fi access
Hybrid PoF cable1 fibre + copperG.657A2, 3 / 20 / 50 m, SC/UPCData + power to the ceiling

The 12 W per port is the splitter rating. The actual load must include the ONU, the radio and cable loss; leave at least 20% headroom.

Engineering features

What changes on site.

No mains at the ceiling

The AP gets 48 V DC over the same cable that carries the PON signal. No local socket, no electrician visit, no extra surge path at the ceiling.

200 m, not 100 m

The hybrid link reaches 200 m per port, twice the 100 m copper Ethernet limit. That covers a long corridor, a warehouse bay or a pole outside the building.

Wi-Fi 6 at the edge

AX3000 dual-band radio with five internal antennas, zero-touch provisioning and seamless roaming across ceiling units.

Isolated power path

The fibre is dielectric; the power pair is separate from the data path. The design removes the copper Ethernet run that normally brings surge into the ceiling.

Eight ports per splitter

One splitter feeds eight APs. A second splitter on the cascade port takes the count to 16; the cascade adds ≤2.3 dB to the optical budget.

Managed as one PON

The gateway’s built-in AC and the OLT manage the APs as one network: SSIDs, VLANs, firmware and roaming policy in one place.

Selection guide

Which configuration fits which site.

Start from the site, not from the model. The table is a starting point; the final check is the optical and power budget.

LayoutSplittersAPsNote
Small floor / 8 rooms1Up to 8One 120 W adapter; check total load ≤96 W
Two floors / 16 rooms2Up to 16Cascade the second splitter; add 2.3 dB optical loss
Corridor + outdoor pole14–6Keep 20% power headroom for cable and radio peak
Mixed PoF + PoE1 splitter + PoE switch8 PoF APs + PoE camerasSeparate power domains; do not parallel the 48 V rails

Do not exceed eight powered outputs on one splitter. For loads above 12 W per port, use a local PoE injector or a higher-power PoF design.

Integration

Where it sits in the chain.

The PoF chain starts at the optical gateway, passes through the power splitter and ends at the ceiling ONU. The optical budget and the 48 V DC budget are calculated together.

  • One bill of materials for the whole chain
  • Connector polish and PON mode confirmed before order
  • Model-level test data supplied with the shipment
Send the site details
Power over Fiber topologyAn optical gateway feeds a PoF power splitter with 8 outputs and a cascade port. A hybrid cable carries fibre data and 48 V DC up to 200 metres to ceiling PoF access points at up to 12 watts per port.HEADENDOptical gateway1× GPON + 2× GE1× 10GE SFP+fibre + DCDISTRIBUTIONPoF splitter8 outputs + cascade120 W · 48 V DC≤ 12 W / port1×9 PLC · ≤16.5 dBPoF AP — ceilingWi-Fi 6 AX3000PoF AP — ceiling12 W max loadPoF AP — corridorzero-touchPoF camera / readerunder 12 W200 m · NO MAINS AT THE ENDPOINTSOLID = FIBRE · DASHED = 48 V DC

Related equipment

Complete the chain.

The product is quoted as part of a chain. These are the parts that usually travel with it.

01PoF power splitter with eight blue output ports and status LEDs

Power over Fiber · splitter

PoF Power Splitter

Eight outputs, 12 W each, one cascade port.

A 1×9 PoF power splitter that combines an optical splitter and a 48 V DC power distributor in one box. It feeds eight PoF ONUs at up to 12 W each to 200 m and provides a cascade port for a second splitter.

Split
1×9 (8 + cascade)
Output power
≤12 W per port
Supply
48 V DC, 120 W
Insertion loss
≤16.5 dB output

Best for Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power

View specifications
02Hybrid PoF cable with two SC/UPC connectors

Power over Fiber · cable

Hybrid PoF Cable

G.657A2 fibre and copper in one flat jacket.

A flat hybrid cable with one G.657A2 fibre and a copper pair, terminated SC/UPC and supplied in 3, 20 or 50 m lengths. Attenuation is ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm; the jacket is rated −20 to +80 °C.

Fibre
G.657A2, single core
Attenuation
≤0.4 / ≤0.3 dB/km
Lengths
3 / 20 / 50 m
Temperature
−20 to +80 °C

Best for Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power

View specifications
03GPON OLT with multiple PON ports and SFP uplinks

PON access · OLT

GPON OLT

From a 1-PON gateway to a 112-PON headend.

GPON OLT platforms for FTTH, campus and hotel access: 2.5 Gbps downstream and 1.25 Gbps upstream, 1:64 split per PON port and 20 km reach on Class B+ optics. Configurations run from a compact 1-PON gateway with built-in AC to a chassis with up to 112 PON ports.

Line rate
2.5 Gbps ↓ / 1.25 Gbps ↑
Max split
1:64 per PON port
Reach
20 km, Class B+
PON ports
1 – 112

Best for FTTH Access Network · Campus Fibre Network · Outdoor Wireless Coverage

View specifications
04PoE ONU with multiple powered Ethernet ports

PON access · PoE ONU

PoE ONU & Reverse PoE

Power the ONU from the LAN, or the LAN from the ONU.

PoE ONU variants for corridors, rooms and MDUs: reverse-PoE (PD) units powered by a PoE switch, PSE units that power cameras and APs, and 4/8/24-port models for floor distribution. One XPON uplink, up to 24 PoE outputs.

Uplink
XPON / 10G PON
PoE ports
1 – 24
Modes
PSE / PD
Power
802.3af/at

Best for CCTV & Surveillance Power · Campus Fibre Network · Outdoor Wireless Coverage

View specifications

Product FAQ

PoF Switch & PoF ONU: questions before the order.

If your question is not here, send the site details and we will answer with the calculation, not a brochure.

Ask an engineer

Is PoF the same as PoE over fibre?

No. PoE sends DC over copper Ethernet pairs. PoF as used here sends DC over the copper conductors in a hybrid fibre cable, alongside the optical fibre. It is not a standard IEEE PoE mode and does not run over a standard patch cord.

How much power is available at 200 m?

The splitter output is rated at up to 12 W per port with a 120 W supply. Voltage drop in the copper pair reduces the power available at the far end; the actual figure depends on cable length and load. Calculate with the cable resistance and leave at least 20% headroom.

Can I power a PTZ camera over PoF?

Only if its steady and peak draw stay within the 12 W port budget, including heater and pan/tilt peaks. Most PTZ cameras with heaters exceed that; use a local mains feed or a higher-power PoF design for those.

What happens if the copper pair shorts?

The splitter’s output protection limits the fault current. Use a fused or current-limited 48 V supply and protect the outdoor cable at the entry point. The optical path is unaffected by the electrical fault.

How many splitters can I cascade?

The splitter has one cascade port with ≤2.3 dB insertion loss. Cascading two splitters is common for 16 APs; each additional stage adds loss and reduces the optical margin, so calculate the PON budget before adding a third.

Does the ceiling ONU need a separate power adapter?

No in the PoF configuration; it is powered over the hybrid cable. A DC 12 V adapter is available as an option for bench testing or a non-PoF site.

Is the system compatible with a third-party OLT?

The ONU is XPON and can register on a compatible GPON/EPON OLT, but the zero-touch AC and roaming features are tied to the gateway/OLT ecosystem. Confirm the OLT and firmware before mixing vendors.

Next step

Need a PoF Switch & PoF ONU configuration checked?

Send the endpoint count, the longest run, the power condition and the destination. We reply with the configuration, the optical/power budget and the quotation assumptions.