Power over Fiber · distribution node

V1809P — 1×9 PoF Power Splitter

A 1×9 PoF power splitter that combines a PLC optical splitter and a 48 V DC power distributor in one enclosure. It feeds eight PoF ONUs at up to 12 W each to 200 m and provides a cascade port for a second splitter.

Updated October 24, 2026

Model code
V1809P
Configuration family
PoF Power Splitter
Split
1×9 (8 + cascade)
Output power
≤12 W per port
PoF power splitter with eight output ports and status LEDs

What this model is for

1×9 PoF Power Splitter

Specifications are taken from the model datasheet. Final configuration is confirmed on the quotation.

V1809P is the distribution point of a Power-over-Fiber network. One hybrid cable arrives from the gateway; eight hybrid cables leave to ceiling APs, cameras or readers. Inside the box, a 1×9 PLC splits the optical signal and a 48 V bus splits the DC power.

The optical ratings are the ones that matter for the link budget: ≤16.5 dB insertion loss on each output, ≤2.3 dB on the cascade port, 1260–1650 nm operating range and a choice of SC/UPC or SC/APC connectors. The power side is rated 48 V DC in and out, 0.25 A nominal and 0.5 A maximum per port, from a 120 W adapter.

At 48 V, 0.25 A is 12 W; the 0.5 A ceiling is a short-term limit, not a continuous load rating. Mount it on a wall or a desktop near the gateway, keep the hybrid cable bends above the minimum radius and label each output with the AP or camera it feeds.

Verified specifications

Verified technical specifications.

ParameterVerified value
Split ratio1×9 (8 output ports + 1 cascade port)
Output insertion loss≤16.5 dB
Cascade insertion loss≤2.3 dB
Operating wavelength1260 – 1650 nm
ConnectorSC/UPC or SC/APC
Input / output voltage48 V DC / 48 V DC
Power supply120 W adapter
Output current0.25 A rated; 0.5 A maximum per port
Outputs8
PoE protocolPoE+ / PoE, IEEE 802.3at/af
Dimensions180 × 120 × 26 mm
InstallationDesktop or wall mounted

Power per port is a rating, not a guarantee at every cable length. Calculate voltage drop for the actual hybrid cable and load.

Engineering highlights

What changes on site.

Optical and power in one node

One enclosure splits the light and the 48 V bus, so the installer terminates one input and eight outputs instead of building a separate power distribution board.

Cascade without a second headend

The cascade port drives a second splitter for 16 APs. It adds ≤2.3 dB, far less than a second home-run fibre.

Per-port protection

Each output is current-limited. A short on one drop does not remove power from the other seven.

Small enough for a riser

180 × 120 × 26 mm, wall or desktop mount. It fits a telecom box, a riser cupboard or the back of a ceiling access panel.

Standard 48 V ecosystem

48 V DC input matches common PoE supplies and battery plants; the output is compatible with 802.3af/at loads through the PoF ONU.

Labelled outputs

Number each output and record it on the as-built. Fault finding on a PoF floor starts with the port number, not with a tone probe.

Parts that complete the chain

Parts that complete the chain.

01PoF power splitter with eight optical power outputs

Power over Fiber · access

PoF Switch & PoF ONU

One hybrid cable to the ceiling: data and 12 W.

A Power-over-Fiber access set: an optical gateway, an 8-output PoF power splitter, hybrid PoF cable and a ceiling Wi-Fi 6 ONU. Each output delivers up to 12 W to 200 m, so ceiling APs and cameras run without a local mains socket.

Power per port
Up to 12 W
Reach
Up to 200 m
Outputs
8 + 1 cascade
Wi-Fi
Wi-Fi 6 AX3000

Best for Outdoor Wireless Coverage · Campus Fibre Network · Parking Lot Camera System

View specifications
02Hybrid PoF cable with two SC/UPC connectors

Power over Fiber · cable

Hybrid PoF Cable

G.657A2 fibre and copper in one flat jacket.

A flat hybrid cable with one G.657A2 fibre and a copper pair, terminated SC/UPC and supplied in 3, 20 or 50 m lengths. Attenuation is ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm; the jacket is rated −20 to +80 °C.

Fibre
G.657A2, single core
Attenuation
≤0.4 / ≤0.3 dB/km
Lengths
3 / 20 / 50 m
Temperature
−20 to +80 °C

Best for Outdoor Wireless Coverage · Parking Lot Camera System · Bollard & Access Control Power

View specifications
03Fiber distribution box with PLC splitters and SC adapters

PON access · ODN

Fiber Optic Splitter (PLC)

1×2 to 1×64, SC/UPC or SC/APC.

Planar lightwave circuit splitters from 1×2 to 1×64 for PON ODN construction. Typical insertion loss runs from 3.6 dB at 1×2 to 20.5 dB at 1×64; each batch ships with test data and the connector polish you specify.

Ratios
1×2 – 1×64
Wavelength
1260 – 1650 nm
Insertion loss
3.6 – 20.5 dB
Connector
SC/UPC / SC/APC

Best for FTTH Access Network · Campus Fibre Network · CCTV & Surveillance Power

View specifications
04Ceiling-mount Wi-Fi access point with PoE and fibre ports

CPE & wireless · access points

Wi-Fi AP & AC

Ceiling, wall-plate and high-density APs.

Wi-Fi 6/7 access points and software AC for hotels, campuses and offices: ceiling APs with 2.5GE PoE, wall-plate APs, high-density models, PoF ceiling APs and a built-in or software AC.

Wi-Fi
Wi-Fi 6 / Wi-Fi 7
Uplink
GE / 2.5GE / PoF
Power
PoE / PoF
Management
AC / OLT

Best for Campus Fibre Network · Outdoor Wireless Coverage · FTTH Access Network

View specifications

Model questions before the order

V1809P: questions before the order

If your question is not here, send the site details and we will answer with the calculation, not a brochure.

Ask an engineer

Is this the same as a PLC optical splitter?

It contains a 1×9 PLC, but it also distributes 48 V DC. A standard PLC splitter only splits light and cannot power a PoF ONU.

How much power reaches the ONU at 50 m?

The port is rated 12 W at 48 V. At 50 m the copper loop resistance reduces the voltage; the ONU input range and the cable cross-section decide the usable power. Use the cable resistance from the datasheet and leave 20% headroom.

Can I mix PoF and standard PON ONUs on the same splitter?

The optical outputs can feed standard ONUs, but only PoF ONUs accept power over the hybrid cable. A standard ONU needs its own DC adapter.

What connector polish should I order?

Choose SC/UPC or SC/APC to match the gateway and ONU. Do not mix polish types without hybrid patch cords; a mismatch adds loss and reflection.

Does the splitter need a ground?

The enclosure is passive, but the 48 V supply and the building bonding system determine the grounding. Follow local electrical code and bond the supply return at one point only.

Can two V1809P units be cascaded?

Yes, through the cascade port. Each stage adds insertion loss, and the second splitter shares the 120 W supply budget. Calculate the optical margin and the total load before adding the second unit.

Next step

Need V1809P checked against your site?

Send the endpoint count, the longest run, the power condition and the destination. We return the optical/power budget and the quotation assumptions.

No obligation. The plan states its assumptions so your engineer can check it.